Key result
3D speckle-tracking echocardiography innovations improve identification of delayed mechanical activation in heart failure.
Why the study?
Does 3D speckle-tracking echocardiography (including area tracking and activation imaging) improve the assessment of mechanical dyssynchrony and selection of heart failure patients for cardiac resynchronisation therapy compared to conventional 2D echocardiographic techniques?
Does 3D speckle-tracking echocardiography (including area tracking and activation imaging) improve the assessment of mechanical dyssynchrony and selection of heart failure patients for cardiac resynchronisation therapy compared to conventional 2D echocardiographic techniques?
Answers are grounded in this paper and cite their sources.
Emerging 3D speckle-tracking echocardiography modalities like area tracking and activation imaging overcome 2D out-of-plane motion limitations to better quantify mechanical dyssynchrony and potentially improve patient selection for cardiac resynchronization therapy.
Wall motion tracking is a relatively new tool to define regional and global wall motion, ventricular volumes and ejection fraction. Speckle-tracking echocardiography (STE) allows the calculation of a variety of myocardial function indices – including longitudinal, radial, transverse and circumferential strain, strain rate, displacement, velocity and rotation (twist and torsion) – not only as a 2D application, but also in 3D. In patients with heart failure and cardiac dyssynchrony, there remains a lack of optimal management regarding decisions to implant a cardiac resynchronisation therapy device. Many decisions are made based on data from electrocardiography. Whereas conventional echocardiographic techniques are of limited value in defining mechanical dyssynchrony, newer developments, such as 2D and 3D speckle tracking, have been shown to have significant potential to define the latest site of mechanical activation. Recent 3D STE innovations, including activation imaging, 3D strain and area tracking, open new doors to the definition of segmental delay of mechanical deformation related to time. There is considerable optimism that 3D techniques will improve the present understanding and treatment of patients with cardiac dyssynchrony.
No takes yet. Share an insight, caveat, or question.
Hans Joachim Nesser (2012) conducted a review in Heart failure and cardiac dyssynchrony. 2D and 3D speckle-tracking echocardiography (STE), including area tracking and activation imaging vs. Conventional echocardiographic techniques (M-mode, pulsed Doppler, tissue Doppler imaging) was evaluated. Three-dimensional speckle-tracking echocardiography innovations, including activation imaging and area tracking, improve identification of delayed mechanical activation in heart failure patients.
Synapse has enriched 10 related papers. Consider them for comparative context: