Key result
Radial artery flow volume center frequency correlates with flow velocity and systolic vessel diameter.
Why the study?
How do fluctuations in radial artery blood flow volume relate to fluctuations in vessel diameter and blood flow velocity at low and high frequencies in healthy adults at rest?
Cross-Sectional (n=33)
No
How do fluctuations in radial artery blood flow volume relate to fluctuations in vessel diameter and blood flow velocity at low and high frequencies in healthy adults at rest?
This pilot study demonstrates that radial artery blood flow volume fluctuations at the traditional pulse diagnosis site are driven primarily by blood flow velocity at low frequencies and by vessel diameter at high frequencies.
Answers are grounded in this paper and cite their sources.
Extends spectral analysis of cardiovascular fluctuations to radial volume at pulse sites; hypothesis-generating, should not yet change practice.
BACKGROUND: Radial artery (RA) pulse diagnosis has been used in traditional Asian medicine. Blood pressure (BP) and pulse rate related to heart rate variability (HRV) can be monitored via the RA. The fluctuation in these parameters has been assessed using fast Fourier transform (FFT) analytical methods that calculate power spectra. METHODS: = 34) were enrolled. We measured the hemodynamics of the right RA for approximately 50 s using ultrasonography. RESULTS: The parameters showed the center frequency (CF) of the power spectrum at low frequency (LF) and high frequency (HF). More than one spectral component indicated that there were fluctuations. The CF at LF for Volume was significantly different from that for vessel diameter (VD); however, it was significantly correlated with blood flow velocity (Velocity). On the other hand, the CF at HF for Volume was significantly different from that for Velocity; however, it was significantly correlated with VD. CONCLUSION: It is suggested that fluctuation in the Volume at LF of RA is influenced by the fluctuation in Velocity; on the other hand, fluctuation in the Volume at HF is influenced by the fluctuation in VD.
No takes yet. Share an insight, caveat, or question.
Watanabe et al. (2016) conducted a cross-sectional in Healthy volunteers undergoing radial artery hemodynamic fluctuation evaluation (n=33). High-resolution ultrasonography with fast Fourier transform spectral analysis of the right radial artery was evaluated on Correlation of center frequency (CF) of power spectrum for radial artery blood flow volume (Volume) with blood flow velocity (Velocity) at low frequency (LF) and systolic vessel diameter (Sys-VD) at high frequency (HF) (p=<0.01). Radial artery blood flow volume center frequency correlated with flow velocity in the low-frequency band (r=0.64, p<0.01) and with systolic vessel diameter in the high-frequency band (r=0.39, p<0.05).