Why the study?
Thrombotic and haemorrhagic complications occur after TAVI, but perioperative changes in coagulation and platelet function are poorly understood, and clear guidelines for antithrombotic therapy are lacking.
How does transcatheter aortic valve implantation affect perioperative coagulation and platelet contribution to clot strength in patients with severe aortic stenosis?
How does transcatheter aortic valve implantation affect perioperative coagulation and platelet contribution to clot strength in patients with severe aortic stenosis?
Following TAVI, patients exhibit an early increase in overall coagulation but a significant decrease in platelet contribution to clot strength, highlighting complex perioperative hemostatic changes.
TEG may detect perioperative coagulation changes after TAVI; leaves open antithrombotic guidance pending randomized trials.
Introduction Thrombotic and haemorrhagic complications have been reported following transcatheter aortic valve implantation (TAVI). However, few reports have studied perioperative changes in coagulation and platelet function after TAVI. Furthermore, there are no clear guidelines for antithrombotic therapy. This study aimed to examine the perioperative changes in coagulation and platelet contribution to clot strength after TAVI using thromboelastography (TEG 6s; Hemonetics). Methods This prospective observational study included 15 patients scheduled to undergo TAVI for severe aortic stenosis. TEG 6s global haemostasis was used to record three measurements: on the day of surgery (immediately before the operation) and postoperative days 1 and 3. The reaction time R to thrombosis; K and α, which represent the rate of thrombosis; and the maximum amplitude (MA) were measured from the kaolin thromboelastography (TEG) curves. The coagulation index (CI) was calculated from the measurement results to assess thrombotic tendency. In addition, MA was converted to elastic clot strength, and platelet function was assessed by the difference, G p , in elastic strength depending on platelet activation. Results R and K decreased, and α tended to increase in kaolin TEG on days 1 and 3 after TAVI, indicating elevated coagulation function compared with the preoperative period, but MA and CI did not show significant changes. G p decreased significantly on days 1 and 3, suggesting a decrease in the platelet contribution to clot strength. Conclusions Compared with the preoperative period, coagulation tended to increase, and platelet contribution to clot strength decreased from days 1 to 3 after TAVI.
No takes yet. Share an insight, caveat, or question.
Sajima et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: