Key result
All-systolic rest perfusion with a long saturation time increased myocardium-peak pre contrast by 59% and reduced blood-to-myocardium signal ratio compared to a conventional short saturation time protocol.
Why the study?
To enable all-systolic first-pass rest myocardial perfusion with long saturation times, and investigate changes in perfusion contrast and dark rim artefacts.
Does an all-systolic first-pass myocardial rest perfusion sequence with long saturation time using SMS and CS improve perfusion contrast and reduce dark rim artefacts compared to a conventional clinical protocol in patients undergoing CMR?
Does an all-systolic first-pass myocardial rest perfusion sequence with long saturation time using SMS and CS improve perfusion contrast and reduce dark rim artefacts compared to a conventional clinical protocol in patients undergoing CMR?
Effect estimate: 59% relative increase
p-value: p=<0.001
An all-systolic rest perfusion CMR sequence combining simultaneous multi-slice and compressed sensing acceleration with long saturation times significantly improves myocardium-perfusion defect contrast and reduces dark rim artefacts compared to conventional protocols.
May enable all-systolic perfusion imaging; leaves open clinical validation and artefact reduction in patients.
PURPOSE: To enable all-systolic first-pass rest myocardial perfusion with long saturation times. To investigate the change in perfusion contrast and dark rim artefacts through simulations and surrogate measurements. METHODS: Simulations were employed to investigate optimal saturation time for myocardium-perfusion defect contrast and blood-to-myocardium signal ratios. Two saturation recovery blocks with long/short saturation times (LTS/STS) were employed to image 3 slices at end-systole and diastole. Simultaneous multi-slice balanced steady state free precession imaging and compressed sensing acceleration were combined. The sequence was compared to a 3 slice-by-slice clinical protocol in 10 patients. Quantitative assessment of myocardium-peak pre contrast and blood-to-myocardium signal ratios, as well as qualitative assessment of perceived SNR, image quality, blurring, and dark rim artefacts, were performed. RESULTS: Simulations showed that with a bolus of 0.075 mmol/kg, a LTS of 240-470 ms led to a relative increase in myocardium-perfusion defect contrast of 34% ± 9%-28% ± 27% than a STS = 120 ms, while reducing blood-to-myocardium signal ratio by 18% ± 10%-32% ± 14% at peak myocardium. With a bolus of 0.05 mmol/kg, LTS was 320-570 ms with an increase in myocardium-perfusion defect contrast of 63% ± 13%-62% ± 29%. Across patients, LTS led to an average increase in myocardium-peak pre contrast of 59% (P < .001) at peak myocardium and a lower blood-to-myocardium signal ratio of 47% (P < .001) and 15% (P < .001) at peak blood/myocardium. LTS had improved motion robustness (P = .002), image quality (P < .001), and decreased dark rim artefacts (P = .008) than the clinical protocol. CONCLUSION: All-systolic rest perfusion can be achieved by combining simultaneous multi-slice and compressed sensing acceleration, enabling 3-slice cardiac coverage with reduced motion and dark rim artefacts. Numerical simulations indicate that myocardium-perfusion defect contrast increases at LTS.
No takes yet. Share an insight, caveat, or question.
Ferrazzi et al. (2021) studied Referred for clinical nonstress contrast-enhanced CMR (n=10). All-systolic first-pass myocardial rest perfusion with long saturation time (LTS) vs. Conventional short saturation time (STS) protocol was evaluated on Myocardium-peak pre (M-PP) contrast (59% relative increase, p=<0.001). All-systolic rest perfusion with a long saturation time increased myocardium-peak pre contrast by 59% and reduced blood-to-myocardium signal ratio compared to a conventional short saturation time protocol.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: