Key result
A unified framework based on convolutional neural networks automated carotid intima-media thickness video interpretation, achieving a mean absolute measurement error of 2.8 µm compared to expert annotations.
A unified CNN-based framework can fully automate carotid intima-media thickness video interpretation with high accuracy, potentially facilitating its use in clinical practice for cardiovascular risk assessment.
May streamline CIMT video analysis in research; leaves open clinical impact on CVD risk prediction.
Cardiovascular disease (CVD) is the leading cause of mortality yet largely preventable, but the key to prevention is to identify at-risk individuals before adverse events. For predicting individual CVD risk, carotid intima-media thickness (CIMT), a noninvasive ultrasound method, has proven to be valuable, offering several advantages over CT coronary artery calcium score. However, each CIMT examination includes several ultrasound videos, and interpreting each of these CIMT videos involves three operations: (1) select three end-diastolic ultrasound frames (EUF) in the video, (2) localize a region of interest (ROI) in each selected frame, and (3) trace the lumen-intima interface and the media-adventitia interface in each ROI to measure CIMT. These operations are tedious, laborious, and time consuming, a serious limitation that hinders the widespread utilization of CIMT in clinical practice. To overcome this limitation, this paper presents a new system to automate CIMT video interpretation. Our extensive experiments demonstrate that the suggested system significantly outperforms the state-of-the-art methods. The superior performance is attributable to our unified framework based on convolutional neural networks (CNNs) coupled with our informative image representation and effective post-processing of the CNN outputs, which are uniquely designed for each of the above three operations.
No takes yet. Share an insight, caveat, or question.
Shin et al. (2017) studied Cardiovascular disease risk assessment (n=23). CNN-based automated CIMT video interpretation system vs. Expert manual measurement and prior hand-crafted algorithms was evaluated on Intima-media thickness measurement error (mean absolute error 2.8 µm). A unified framework based on convolutional neural networks automated carotid intima-media thickness video interpretation, achieving a mean absolute measurement error of 2.8 µm compared to expert annotations.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: