This report describes a new balloon pulmonary valvuloplasty technique using the Inoue balloon catheter performed in 14 consecutive adult patients, aged 17-47 years (mean 27). The mean right ventricular systolic pressure and the pulmonary valvular peak-to-peak systolic gradient decreased from 102 +/- 41 to 52 +/- 19 mm Hg (p = 0.001) and 81 +/- 40 to 7 +/- 7 mm Hg (p = 0.0002), respectively. An infundibular peak-to-peak systolic gradient either developed (n = 13) or increased (n = 1). None of the patients were treated with beta-adrenergic blockers before or after the valvuloplasty. Eight patients underwent repeat hemodynamic study 12-30 months (mean 17) after treatment, and had no evidence of valvular restenosis. The mean right ventricular systolic pressure and the mean infundibular peak-to-peak systolic gradient decreased, compared to the values immediately after valvuloplasty (54 to 40 mm Hg, p = 0.03, and 28 to 10 mm Hg, p = 0.03, respectively). The study suggests that pulmonary valvuloplasty in adults using the Inoue balloon catheter technique is feasible, safe, and effective.
No takes yet. Share an insight, caveat, or question.
Lau et al. (1993) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: