Overhang is a useful structure for increasing the torque and power densities of permanent-magnet (PM) machines without expansion of the machine space. A 3-D finite-element method (FEM) is needed to evaluate the performances of PM machines with an overhang structure because the overhang structure results in non-uniform magnetic flux distributions in the axial direction. However, it is computationally expensive, especially in the early design stage. In this paper, we propose a magnetic equivalent circuit (MEC) model considering the overhang effects of interior PM (IPM) machines. With the proposed MEC, the performances of IPM machines with an overhang structure were precisely calculated and the computational time was significantly reduced. The proposed MEC was verified by the 3-D FEM.