This paper proposes a diagnosis technique algorithm for a brushless dc motors under a stator inter-turn fault (ITF) condition using input impedance. The algorithm has early detection and various speed-range detection advantages. To early and accurately detect the ITF, the rotating speed, input current, voltage, resistance, and inductance must be analyzed. Therefore, we choose the input impedance as the detection factor because it includes all these factors. In this paper, the fault-detection system works without requiring a fast Fourier transform and the calculation of the negative-sequence impedance from the comparison of the measured impedance with the database impedance. The proposed technique was verified by the simulation and experiment.