Answers are grounded in this paper and cite their sources.
Selective acetylene hydrogenation over a commercial Pd‐Ag/Al 2 O 3 catalyst was carried out under industrial operation conditions that correspond to the “tail‐end” process. Pyrolysis gas chromatography‐mass spectrometry was used to analyze the composition of the green oil. C8–C30 linear hydrocarbons with even carbon‐numbered chains were detected as the main components of the green oil. Its chain length increased with operating time, temperature, and hydrogen partial pressure, and decreased with acetylene partial pressure. The composition of the green oil deviates from the Anderson‐Schulz‐Flory distribution. Both coupling‐hydrogenation and hydrogenation‐coupling mechanisms are involved in green oil formation.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: