Key result
Increasing numbers of off-label characteristics for drug-eluting stents were associated with a stepwise increase in 5-year MACE rates, from 16.7% with zero to 32.7% with five characteristics.
Why the study?
Does an increasing number of off-label characteristics increase the rate of MACE in patients receiving first-generation drug-eluting stents?
Cohort (n=2,098)
Yes
Does an increasing number of off-label characteristics increase the rate of MACE in patients receiving first-generation drug-eluting stents?
An increasing number of off-label characteristics in coronary lesions treated with first-generation drug-eluting stents is associated with a stepwise increase in 5-year MACE rates, suggesting that individualized stent selection could improve clinical outcomes.
May inform off-label DES selection; leaves open whether lesion-guided brand choice improves 5-year outcomes.
Objective: We explored the impact of increasing number of off-label patient and lesion character-istics on 5-year clinical outcome following implantation of first generation drug eluting stents. Furthermore we tried to assess if stent performance might be improved if the off-label character-istics present were taken into account to guide the stent brand selection. Design: A total of 2888 coronary lesions treated with first generation drug eluting stents were classified for eventual presence of 18 different off-label characteristics and correlated to the 5-year clinical outcome by multiple stepwise Cox regression analysis. Results: The composite of cardiac death, myocardial infarction and target vessel revascularization (major adverse cardiac event, MACE) was 16.7% in cases with zero off-label characteristics and showed a stepwise increased rate up to 32.7% in cases with 5 off-label characteristics. The MACE rate for the sirolimus eluting stent appears to be 10% lower than the paclitaxel stent group and it may be further reduced by 10% - 18% if the off-label characteristics present in each case were taken into account to guide the stent brand selection. Conclusion: With increasing number of concomitantly appearing off-label characteristics there is a stepwise increase in MACE rate. The MACE rate may be reduced if the off-label characteristics were used to guide the stent brand selection.
No takes yet. Share an insight, caveat, or question.
Galløe et al. (2016) conducted a cohort in Coronary artery disease requiring stenting (n=2,098). Increasing number of off-label indications for drug-eluting stents vs. Zero off-label indications was evaluated on Major adverse cardiac events (cardiac death, myocardial infarction, and target vessel revascularization) at 5 years (p=<0.0001). Increasing numbers of off-label characteristics for drug-eluting stents were associated with a stepwise increase in 5-year MACE rates, from 16.7% with zero to 32.7% with five characteristics.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: