Key result
Commercially available punch trackers (Corner, Hykso, StrikeTec) showed no strong correlations with gold-standard force and velocity data during full-contact punches.
Why the study?
This study determined how well data from commercially available punch trackers (Corner, Hykso, and StrikeTec) related to gold-standard velocity and force measures during full-contact punches.
Cross-Sectional (n=20)
quasi-randomized order
Commercially available punch trackers do not strongly correlate with gold-standard force and velocity measures and should not be used if high precision is required.
Answers are grounded in this paper and cite their sources.
Punch trackers lack strong validity vs. gold-standard measures; leaves open their utility for training feedback pending device improvements.
Omcirk, D, Vetrovsky, T, Padecky, J, Malecek, J, and Tufano, JJ. Validity of commercially available punch trackers. J Strength Cond Res 37(11): 2273-2281, 2023-This study determined how well data from commercially available punch trackers (Corner, Hykso, and StrikeTec) related to gold-standard velocity and force measures during full-contact punches. In a quasi-randomized order, 20 male subjects performed 6 individual rear straight punches, rear hooks, and rear uppercuts against a wall-mounted force plate. Punch tracker variables were compared with the peak force of the force plate and to the peak (QPV) and mean velocity (QMV) assessed through Qualisys 3-dimensional tracking. For each punch tracker variable, Pearson's correlation coefficient, mean absolute percentage error (MAPE), and mean percentage error (MPE) were calculated. There were no strong correlations between punch tracker data and gold-standard force and velocity data. However, Hykso "velocity" was moderately correlated with QMV ( r = 0.68, MAPE 0.64, MPE 0.63) and QPV ( r = 0.61, MAPE 0.21, MPE -0.06). Corner Power G was moderately correlated with QMV ( r = 0.59, MAPE 0.65, MPE 0.58) and QPV ( r = 0.58, MAPE 0.27, MPE -0.09), but Corner "velocity" was not. StrikeTec "velocity" was moderately correlated with QMV ( r = 0.56, MAPE 1.49, MPE 1.49) and QPV ( r = 0.55, MAPE 0.46, MPE 0.43). Therefore, none of the devices fared particularly well for all of their data output, and if not willing to accept any room for error, none of these devices should be used. Nevertheless, these devices and their proprietary algorithms may be updated in the future, which would warrant further investigation.
No takes yet. Share an insight, caveat, or question.
Omcirk et al. (2023) reported a cross-sectional. Commercially available punch trackers (Corner, Hykso, and StrikeTec) vs. Gold-standard velocity and force measures (force plate and Qualisys 3-dimensional tracking) was evaluated on Correlation with gold-standard peak force, peak velocity (QPV), and mean velocity (QMV). Commercially available punch trackers (Corner, Hykso, StrikeTec) showed no strong correlations with gold-standard force and velocity data during full-contact punches.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: