BACKGROUND AND PURPOSE: To assess safety and efficacy data of a new bioactive coil (Cerecyte) which is loaded with polyglycolic acid on the inside of the coil. METHODS: Fifty-four patients harboring 55 aneurysms were treated with Cerecyte coils. These aneurysms were matched in localization and size with aneurysms treated with bare platinum coils. RESULTS: Periprocedural complications and handling did not differ between both groups. Initial aneurysm occlusion was comparable in both treatment groups. At 6 months angiographic follow-up, the aneurysms occluded with Cerecyte coils had a higher chance for complete occlusion (P=0.045) and tended to a lower retreatment rate (P=0.056). CONCLUSIONS: Cerecyte coils are as safe as bare platinum coils in the endovascular occlusion of aneurysms. This matched pair analysis indicates a higher occlusion rate of aneurysms occluded with Cerecyte coils.
No takes yet. Share an insight, caveat, or question.
Bendszus et al. (2007) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: