Aim The aim of this study was to compare the diagnostic performance of whole-body bone scintigraphy (WBS) and multi-field-of-view single photon emission tomography (multi-FOV SPECT) with 99m Tc-oxidronate ( 99m Tc-HDP) in patients with prostate cancer (PCa). Methods In a prospective study, WBS and SPECT acquisitions were performed in194 patients with histologically confirmed PCa and serum prostate-specific antigen (PSA) levels above 10 ng/mL. Scans obtained using the two modalities were interpreted separately. Clinical and biochemical follow-up, radiological studies and biopsies served as benchmarks for the assessments. The impact of PSA level on WBS and SPECT results was also evaluated. Results The patient-based sensitivity, specificity, accuracy, PPV and NPV values of SPECT examinations were higher than those of WBS, especially in patients with serum PSA levels ≶40 ng/mL. Conclusion Multi-FOV SPECT proved to be more sensitive and specific than WBS in detecting bone metastases in PCa patients.
No takes yet. Share an insight, caveat, or question.
Giovanella et al. (2011) studied this question.