This paper presents the torque analysis and measurements of cylindrical air-gap synchronous permanent magnet couplings based on analytical magnetic field calculations. Employing a magnetic vector potential and a 2-D analytical model with two polar coordinate systems, we obtain the magnetic fields produced by permanent magnets. Then, the analytical torque solutions are derived using these magnetic field solutions and a Maxwell stress tensor method. The analytical results are validated by nonlinear 2-D and 3-D finite element results. Finally, torque measurements are presented to show the effectiveness of the analysis.
No takes yet. Share an insight, caveat, or question.
Choi et al. (2013) studied this question.