Key result
Multimodal wearable sensors detect cardiovascular decompensation with ~0.80 AUROC in porcine hypovolemia models.
Answers are grounded in this paper and cite their sources.
Demonstrates wearable multimodal sensing accurately estimates cardiovascular decompensation across absolute and relative hypovolemia in pigs, highlighting potential for trauma triage.
Hypovolemia remains the leading cause of preventable death in trauma cases. Recent research has demonstrated that using noninvasive continuous waveforms rather than traditional vital signs improves accuracy in early detection of hypovolemia to assist in triage and resuscitation. This work evaluates random forest models trained on different subsets of data from a pig model (n = 6) of absolute (bleeding) and relative (nitroglycerin-induced vasodilation) progressive hypovolemia (to 20% decrease in mean arterial pressure) and resuscitation. Features for the models were derived from a multi-modal set of wearable sensors, comprised of the electrocardiogram (ECG), seismocardiogram (SCG) and reflective photoplethysmogram (RPPG) and were normalized to each subject.s baseline. The median RMSE between predicted and actual percent progression towards cardiovascular decompensation for the best model was 30.5% during the relative period, 16.8% during absolute and 22.1% during resuscitation. The least squares best fit line over the mean aggregated predictions had a slope of 0.65 and intercept of 12.3, with an R2value of 0.93. When transitioned to a binary classification problem to identify decompensation, this model achieved an AUROC of 0.80. This study: a) developed a global model incorporating ECG, SCG and RPPG features for estimating individual-specific decompensation from progressive relative and absolute hypovolemia and resuscitation; b) demonstrated SCG as the most important modality to predict decompensation; c) demonstrated efficacy of random forest models trained on different data subsets; and d) demonstrated adding training data from two discrete forms of hypovolemia increases prediction accuracy for the other form of hypovolemia and resuscitation.
No takes yet. Share an insight, caveat, or question.
Kimball et al. (2021) studied Progressive relative and absolute hypovolemia and resuscitation (n=6). Random forest models using multi-modal wearable sensors (ECG, SCG, and RPPG) vs. Actual percent progression towards cardiovascular decompensation was evaluated on Estimation of cardiovascular decompensation status (RMSE and binary classification AUROC) (AUROC 0.80; R2 0.93). Random forest models using wearable ECG, SCG, and RPPG sensors estimated cardiovascular decompensation in a porcine hypovolemia model with an R2 of 0.93 and AUROC of 0.80.
Synapse has enriched 10 related papers. Consider them for comparative context: