This work deals with a novel method of magnetizing inductance investigation using dynamic simulation of self-excited induction generator. As presented in many papers the magnetizing inductance is the main factor of voltage build-up and stabilization of generated voltage for unloaded and loaded conditions. Thus, an accurate model of the dependency of the magnetizing inductance on magnetizing current is crucial for a realistic representation of the voltage build-up. The proposed method is based on a comparison between the data gained from no-load test (only voltage and current measured at stator terminals are needed) and adequate data calculated in the dynamic simulation. The magnetizing inductance curve of a 4.4 kW wound rotor induction machine was investigated by means of the proposed method and the comparison with the measurement is shown and discussed in the conclusion of this paper.
No takes yet. Share an insight, caveat, or question.
Kalamen et al. (2012) studied this question.