Why the study?
Ebstein anomaly is associated with structural and conduction system diseases, but the feasibility of conduction system pacing in a patient with Ebstein anomaly presenting with second-degree Mobitz II AV block had not been reported.
Distal His bundle pacing is feasible and can successfully correct both AV block and RBBB in patients with surgically treated complex Ebstein anomaly.
Alerts clinicians to expanded conduction risks in Ebstein's; leaves open prevalence, screening, and management implications.
Background: Ebstein's anomaly occurs when there is an apical displacement of the tricuspid valve with septal and posterior valve leaflets tethering. This condition often occurs in association with other congenital, structural, or conduction system diseases, including intracardiac shunts, valvular lesions, arrhythmias, accessory conduction pathways, and first-degree atrioventricular (AV) block. We present for the first time a case of a patient with Ebstein's anomaly who presented with second-degree Mobitz II AV block and was successfully treated with conduction system pacing (CSP) due to her young age and the likelihood of a long-term high percentage of pacing. Case summary: We present a case of a 42-year-old lady with a background of complex congenital heart disease, including severe pulmonary stenosis, Ebstein anomaly, and atrial septal defect (ASD). She required complex surgical intervention, including tricuspid valve (TV) repair and subsequently replacement, ASD closure, and pulmonary balloon valvuloplasty. She presented to our hospital with symptomatic second-degree Mobitz II AV block (dizziness, shortness of breath, and exercise intolerance) and right bundle branch block (RBBB) on her baseline ECG. Her echocardiogram showed dilated right ventricle (RV) and left ventricle (LV) with low normal LV systolic function. Due to her young age and the likelihood of a long-term high percentage of RV pacing, we opted for CSP after a detailed discussion and patient consent. The distal HIS position is the preferred pacing strategy at our centre. We could not cross the TV with the standard Medtronic C315 HIS catheter, so we had to use the deflectable C304 HIS catheter. Mapping and pacing of the distal HIS bundle were achieved by Medtronic Selectsecure 3830, 69 cm lead. HIS bundle pacing led to the correction of both second-degree Mobitz II AV block and pre-existing RBBB. The implantation was uneventful, and the patient was discharged home the next day without any acute complications. Discussion: Distal HIS pacing is feasible in patients with surgically treated complex Ebstein anomaly and heart block. This approach can normalize the QRS complex with a high probability of preserving or improving LV function.
No takes yet. Share an insight, caveat, or question.
Koev et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: