Why the study?
While AI models can classify arrhythmias with human-level accuracy, their potential for broad screening using smartwatch-like lead I ECG recordings remains underutilized.
Does a deep learning framework (CARE-I) accurately classify cardiac arrhythmias using 10-second lead I ECG recordings in both clean and noisy environments?
Does a deep learning framework (CARE-I) accurately classify cardiac arrhythmias using 10-second lead I ECG recordings in both clean and noisy environments?
A deep learning framework (CARE-I) can accurately classify cardiac arrhythmias from 10-second lead I ECGs, demonstrating robustness to noise and highlighting the potential for smartwatch-based remote monitoring.
Answers are grounded in this paper and cite their sources.
May support smartwatch ECG screening for arrhythmias; hypothesis-generating and requires prospective validation before clinical use.
OBJECTIVE: Cardiac diseases are a leading cause of global mortality. Electrocardiograms (ECGs) are essential for detecting abnormal cardiac rhythms. Smartwatches can record ECGs, similar to lead I ECGs recorded by a patient vitals monitor in a hospital, potentially helping clinicians in early diagnosis and improved management of cardiovascular diseases. While AI models have classified arrhythmias with human-level accuracy, their potential for broad screening remains underutilized. METHODS: We propose a deep learning based framework for diagnosing various cardiac arrhythmias using 10-second lead I ECG recordings, demonstrating lead I's utility in remote monitoring. Robustness was tested by introducing noise to simulate real-world conditions. Additionally, a novel data similarity assessment metric was developed to enhance transfer learning and external dataset validation. RESULTS: Using over 60,000 ECGs from the PhysioNet Challenge 2021, the trained model classified clean lead I ECGs in one dataset with a test-fold area under receiver operating characteristic curve (AUC), sensitivity, and specificity of 0.915, 0.867 and 0.858 respectively. For signals with 0 dB signal-to-noise ratio from the same dataset, the respective performance metrics dropped slightly to 0.899, 0.862 and 0.818. External validation across three separate datasets showed a minimum AUC of 0.807. The data similarity metric outperformed an existing method in improving classification, particularly with limited target dataset samples, i.e. 50. CONCLUSION: The proposed Cardiac Arrhythmia Risk Evaluation from Lead-I ECG (CARE-I) framework enables accurate arrhythmia detection across diverse populations in real-world noisy environments, thus enhancing model generalisation and early diagnosis.