This paper reports a new design strategy of adding lumped masses to the frame structure of a disk resonator gyroscope (DRG) to mitigate its figure of merit (FOM). A greatly enhanced decaying time constantτcan lead to very small FOM, which could then greatly mitigate the DRG's bias and bias drift. Additionally, this technique could also reduce the Brownian noise floor. A comprehensive investigation of the possible ways to add the lumped masses is presented, and a detailed design guideline is provided. A DRG prototype based on this design strategy is then presented and shows aτof 38.5 s, a quality factorQof 358 k, and a FOM of 1.9°/s. The prototype is operated in the force-to-rebalance mode, and an angle random walk of 0.012°/√h and a bias stability of 0.08°/h are demonstrated experimentally. This design strategy is suitable for use in batch fabrication of very high precision microelectromechanical systems devices such as gyroscopes.