Why the study?
Does transcatheter closure of ASD using the Amplatzer septal occluder improve symptoms and cardiac remodeling in elderly patients with permanent atrial fibrillation?
Does transcatheter closure of ASD using the Amplatzer septal occluder improve symptoms and cardiac remodeling in elderly patients with permanent atrial fibrillation?
Transcatheter closure of ASD in elderly patients with permanent atrial fibrillation is feasible and leads to symptomatic improvement and favorable cardiac remodeling.
Answers are grounded in this paper and cite their sources.
May support ASD closure for remodeling in elderly permanent AF; hypothesis-generating, requiring controlled trials before practice change.
OBJECTIVES: The aim of this study is to evaluate the feasibility and efficacy of device closure of atrial septal defect (ASD) in elderly patients with permanent atrial fibrillation. BACKGROUND: Little is known about the feasibility of device closure of ASD in those patients. METHODS: Nine consecutive patients (mean age 68.1 years) with permanent atrial fibrillation (>1 year persistent) underwent catheter closure using the Amplatzer septal occluder. Transthoracic echocardiography and plasma B-type natriuretic peptide (BNP) level were assessed before and at 24 hours; and 1, 3, and >6 months after the closure. Before the procedure, appropriate dose of warfarin was used in all, diuretics was used in 8/9. Same amount of medications were continued after the procedure. RESULTS: ASD could be closed in all (mean device size 27.3 mm) without hemodynamic and thromboembolic complications. New York Heart Association (NYHA) functional classification was significantly improved in all patients after device closure. No hemodynamic and thromboembolic complications were observed during the follow-up period (mean 10.6 months). Although permanent atrial fibrillation did not change in all after the procedure, resting heart rate decreased from 76.2 +/- 16.0 to 68.3 +/- 13.2 beats/min (P = 0.015). There was statistically significant improvement in right ventricular/left ventricular diameter ratio (1.08 +/- 0.16 to 0.73 +/- 0.10, P = 0.008) and plasma BNP level (183.7 +/- 90.5 to 94.6 +/- 47.4 pg/mL, P = 0.008) after >6 months device closure. CONCLUSIONS: Even in the patients complicated with permanent fibrillation, transcatheter closure of ASD can contribute to symptomatic improvement as well as cardiac geometric remodeling.
No takes yet. Share an insight, caveat, or question.
Taniguchi et al. (2008) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: