Answers are grounded in this paper and cite their sources.
We present differential-absorption photoacoustic imaging, which detects the difference between transient and ground-state absorption, for contrast enhancement based on suppressing undesired objects. Two tubes were imaged. One contains a Pt(II) octaethylporphine (PtOEP) dye solution and serves as an object of interest, while the other contains an IR-783 (from Sigma-Aldrich) dye solution and serves as an object to suppress. Although the IR-783 tube dominates the conventional photoacoustic image, it is suppressed by 43 dB and consequently significantly overwhelmed by the PtOEP tube in the differential-absorption photoacoustic image. Imaging depth in this mode is also discussed.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2009) studied this question.