Why the study?
CTPA detection of pulmonary embolism is limited by contrast bolus timing, physician-dependent diagnostic accuracy, and scan interpretation time.
Does an AI-based PE triaging model (AID-PE) improve diagnostic accuracy and efficiency for detecting pulmonary embolism on CTPA compared to contemporary workflow?
Does an AI-based PE triaging model (AID-PE) improve diagnostic accuracy and efficiency for detecting pulmonary embolism on CTPA compared to contemporary workflow?
An attention-based deep learning network (AID-PE) demonstrates high diagnostic accuracy and significantly faster screening times for pulmonary embolism on CTPA compared to standard radiological workflow.
May accelerate CTPA workflow for PE detection; hypothesis-generating and requires prospective validation before clinical adoption.
Rational and objectives Pulmonary embolism (PE) is the third most fatal cardiovascular disease in the United States. Currently, Computed Tomography Pulmonary Angiography (CTPA) serves as diagnostic gold standard for detecting PE. However, its efficacy is limited by factors such as contrast bolus timing, physician-dependent diagnostic accuracy, and time taken for scan interpretation. To address these limitations, we propose an AI-based PE triaging model (AID-PE) designed to predict the presence and key characteristics of PE on CTPA. This model aims to enhance diagnostic accuracy, efficiency, and the speed of PE identification. Materials and methods We trained AID-PE on the RSNA-STR PE CT (RSPECT) Dataset, N = 7279 and subsequently tested it on an in-house dataset (n = 106). We evaluated efficiency in a separate dataset (D 4 , n = 200) by comparing the time from scan to report in standard PE detection workflow versus AID-PE. Results A comparative analysis showed that AID-PE had an AUC/accuracy of 0.95/0.88. In contrast, a Convolutional Neural Network (CNN) classifier and a CNN-Long Short-Term Memory (LSTM) network without an attention module had an AUC/accuracy of 0.5/0.74 and 0.88/0.65, respectively. Our model achieved AUCs of 0.82 and 0.95 for detecting PE on the validation dataset and the independent test set, respectively. On D 4 , AID-PE took an average of 1.32 s to screen for PE across 148 CTPA studies, compared to an average of 40 min in contemporary workflow. Conclusion AID-PE outperformed a baseline CNN classifier and a single-stage CNN-LSTM network without an attention module. Additionally, its efficiency is comparable to the current radiological workflow.
No takes yet. Share an insight, caveat, or question.
Singh et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: