The VO 2+ crossover, or permeability, through Nafion in a vanadium redox flow battery (VRFB) was monitored as a function of sulfuric acid concentration and VO 2+ concentration. A vanadium rich solution was flowed on one side of the membrane through a flow field while symmetrically on the other side a blank or vanadium deficit solution was flowed. The blank solution was flowed through an electron paramagnetic resonance (EPR) cavity and the VO 2+ concentration was determined from the intensity of the EPR signal. Concentration values were fit using a solution of Fick's law that allows for the effect of concentration change on the vanadium rich side. The fits resulted in permeability values of VO 2+ ions across the membrane. Viscosity measurements of many VO 2+ and H 2 SO 4 solutions were made at 30–60°C. These viscosity values were then used to determine the effect of the viscosity of the flowing solution on the permeability of the ion.
No takes yet. Share an insight, caveat, or question.
Lawton et al. (2013) studied this question.