Why the study?
Does machine-derived central aortic blood pressure differ significantly from manually or machine-measured peripheral blood pressure in cardiology outpatients?
Does machine-derived central aortic blood pressure differ significantly from manually or machine-measured peripheral blood pressure in cardiology outpatients?
Central aortic systolic pressure is significantly lower than manually recorded peripheral systolic pressure, highlighting potential discrepancies when relying solely on peripheral measurements.
Answers are grounded in this paper and cite their sources.
May warrant caution relying solely on peripheral SBP in outpatients; leaves open whether central measurements improve risk prediction.
Background Of late, central aortic blood pressure (CABP) has emerged as a better parameter than peripheral blood pressure (BP) in the diagnosis of cardiovascular events. Advent of new technologies has facilitated the calculation of CABP from machine-derived peripheral BP. In this study, the author determined the differences between peripheral BP measured manually or by machine and machine-derived CABP and examined whether this difference is stable even after categorizing the sample pool based on sex, hypertension, diabetes status, and β-blocker use. Materials and Methods A total of 83 patients (both male and female) who attended the cardiology outpatient department were enrolled in the study. BP was recorded both manually and using Mobil-O-Graph pulse wave analyzer (ARC Solver) in the patient's sitting posture. The author compared the derived central, manual, and device-measured BP among the patient samples and assessed whether sex, hypertension, diabetes, and β-blocker use influence these differences. Results Among the study population, 28 were females and 55 were males; patients’ mean age was 59.97 ± 12.15 years. The mean peripheral systolic BP (SBP) and diastolic BP (DBP) measured manually were127.55 ± 20.15 and 79.73 ± 9.57 mm Hg, respectively. Similar measurements recorded by the device were 129.68 ± 19.93 and 78.92 ± 13.48, respectively. The derived mean central aortic SBP and DBP was 117.69 ± 17.78 and 80.15 ± 13.71, respectively. Statistically significant difference in the manual and central aortic SBP (9.85 ± 11.16; p < 0.0001) was observed. This difference was significant irrespective of sex, hypertension, diabetes status, and β-blocker use. Similarly, difference between machine-derived peripheral SBP and central aortic SBP was statistically significant (p < 0.0001). However, the difference in manual and central aortic DBP was nonsignificant (p = 0.6976). Interestingly, a small (−1.34 ± 2.28) but statistically significant difference (p < 0.0001) between machine-derived peripheral DBP and central aortic DBP was observed. Further analysis to find out effect of β-blocker use on CABP revealed that the central aortic SBP is slightly, but statistically significantly, lower in β-blocker users (117.7 ± 17.71; p < 0.0001) than that of β-blocker nonusers (118.9 ± 18.37; p< 0.0001). Conclusion Central aortic systolic pressure is statistically significantly lower than the manually recorded peripheral SBP irrespective of sex, hypertension, diabetes status, and β-blocker use. A small but significant difference was observed between machine-derived peripheral DBP and central aortic DBP. Patients using β-blockers were observed to have marginally lower CABP values than those who are not using them.
No takes yet. Share an insight, caveat, or question.
Hemamalini Padma Kavirayani (2017) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: