While lithium hexafluorophosphate (LiPF 6 ) still prevails as the main conducting salt in commercial lithium-ion batteries, its prominent disadvantage is high sensitivity toward water, which produces highly corrosive HF that degrades battery performance. The hydrolysis mechanism and its correlation with high voltage in the battery environment remain poorly understood, despite the wide application of high voltage cathode. In this work, combining theoretical and experimental approaches, we identified the direct reaction between H 2 O and PF 6 – as main source of HF based on the preferential solvation of PF 6 – anion by water and the low energy barrier for the decomposition of PF 6 – –H 2 O complex. Such a hydrolysis process would be accelerated by high voltage the electrolytes face at the cathode side. This important clarification of electrolyte failure mechanism points us to design more effective mitigation strategies with the purpose of stabilizing LiPF 6 -based electrolytes for high voltage LIBs.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2021) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: