Why the study?
Current automated CCT analysis methods often require manual selection of the region of interest, limiting personalized management and outcome prediction before TAVR.
A fully automated pipeline using a convolutional neural network demonstrated robust performance for aortic root detection and tilt alignment in pre-TAVR cardiac computed tomography.
May support automated pre-TAVR CT analysis; leaves open prospective validation before clinical use.
Background: Automated analysis of cardiac computed tomography (CCT) studies may help in personalized management and outcome prediction of patients undergoing transcatheter aortic valve replacement (TAVR). The current methods are often preceded by a manual selection of the region of interest. To address this limitation, this study aims to develop an object-oriented aortic root detection pipeline. Methods: All consecutive patients who underwent CCT for TAVR procedure, from January to July 2023 at our center, were retrospectively collected. Patients with previous prosthesis or permanent pacemaker were excluded. Baseline bounding box annotations were performed by a single expert, and tilt angle measurements were performed by 2 for interobserver comparison. A pretrained convolutional neural network was used for aortic root detection, and its performance was evaluated by recall, precision, F1, average precision at an intersection over union overlap of 50% and mean average precision (mAP) 50%-95% on 100 unseen test set. For tilt alignment, intensity thresholding, connected component, and principal component analyses were proposed. Results were evaluated by Bland-Altman comparison. Results: Of the 228 TAVR patients with preprocedural CCT, 179 were eligible, and their axial contrast-enhanced CCTs could be retrieved successfully; 100 CCTs were assigned to the test set, and the remaining to the training and validation using a 4:1 split. The model detected the aortic root with recall, precision, and F1 score of 99.0%, for all 3; mAP50 of 99.5%; and mAP50-95 of 60.4%. The tilt prediction algorithm had a mean error of 7.9° (Q1-Q3, -5.3° to 21.1°) compared with 3.3° (Q1-Q3, -6.7° to 13.4°) interobserver difference. Conclusions: This study demonstrates the robust performance of a fully automated pipeline for aortic root detection and analysis of key features in pre-TAVR CCTs. Further prospective studies are required for clinical developments.
No takes yet. Share an insight, caveat, or question.
Mahmoudi et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: