Introduction. Timely and accurate diagnosis of bacterial infections enables early administration of appropriate antimicrobial treatment and improved outcomes. Hypothesis/Gap Statement. The accuracy of computer-aided diagnosis (CAD) for identifying organisms on urine Gram stains has not been compared with that of microbiology specialists (MS). Aim. To compare the interpretation of urine Gram-stain results by MS and a CAD app designed using artificial intelligence. Methodology. Urine specimens from patients with urinary tract infections were used and collected at two tertiary hospitals between 1 April and 31 December 2022. Using non-inferiority analysis to assess whether CAD was non-inferior to expert interpretation, CAD-predicted microscopic findings of the Gram-stained slide generated from iPhone camera images from two hospitals were compared with those from ten MS. A total of 153 images were taken from each hospital, and CAD interpreted a total of 306. The primary endpoint was the prediction accuracy based on the morphology of the Gram-stained bacteria. Results. The accuracy (95% confidence interval) of MS and CAD predictions was 83.0% (81.6%–84.3%) and 87.9% (83.7%–91.3%), respectively, with a difference of –4.93% (–8.43% to –0.62%) indicating non-inferiority of CAD. Conclusion. CAD was non-inferior to MS predictions for identifying Gram-stained pathogens; therefore, CAD was suggested to have the potential for guiding empirical antibiotic selection in patients with urinary tract infections.
No takes yet. Share an insight, caveat, or question.
Yamamoto et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: