Abstract 15 MeV proton irradiation of vertical geometry NiO/ β -Ga 2 O 3 heterojunction rectifiers produced reductions in reverse breakdown voltage from 4.3 kV to 3.7 kV for a fluence of 10 13 ions·cm −2 and 1.93 kV for 10 14 ions·cm −2 . The forward current density was also decreased by 1–2 orders of magnitude under these conditions, with associated increase in on-state resistance R ON . These changes are due to a reduction in carrier density and mobility in the drift region. The reverse leakage current increased by a factor of ∼2 for the higher fluence. Subsequent annealing up to 400 °C further increased reverse leakage due to deterioration of the contacts, but the initial carrier density of 2.2 × 10 16 cm −3 was almost fully restored by this annealing in the lower fluence samples and by more than 50% in the 10 14 cm −2 irradiated devices. Carrier removal rates in the Ga 2 O 3 were in the range 190–1200 for the fluence range employed, similar to Schottky rectifiers without the NiO.
No takes yet. Share an insight, caveat, or question.
Li et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: