The same-source problem remains a major challenge in forensic toolmark and firearm examination. Here, we investigate the applicability of the Chumbley method (J Forensic Sci, 2018, 63, 849; J Forensic Sci, 2010, 55, 953) (10,12), developed for screwdriver markings, for same-source identification of striations on bullet LEAs. The Hamby datasets 44 and 252 measured by NIST and CSAFE (high-resolution scans) are used here. We provide methods to identify parameters that minimize error rates for matching of LEAs, and a remedial algorithm to alleviate the problem of failed tests, while increasing the power of the test and reducing error rates. For 85,491 land-to-land comparisons (84,235 known nonmatches and 1256 known matches), the adapted test does not provide a result in 176 situations (originally more than 500). The Type I and Type II error rates are 7.2% (6105 out of 84,235) and 21.4% (271 out of 1256), respectively. This puts the proposed method on similar footing as other single-feature matching approaches in the literature.