Key result
Pulsed-field ablation and cryoballoon ablation demonstrated comparable acute efficacy, achieving 100% pulmonary vein isolation and 95-100% left atrial roof conduction block (P=0.421).
Why the study?
Pulsed-field ablation systems enable ablation beyond PVI, such as left atrial roof ablation, but the acute efficacy, feasibility, and safety compared to cryoballoon systems in persistent AF had not been established.
Does pulsed-field ablation improve acute procedural success and safety compared to cryoballoon ablation for combined pulmonary vein isolation and left atrial roof ablation in patients with persistent atrial fibrillation?
Observational (n=125)
No
Does pulsed-field ablation improve acute procedural success and safety compared to cryoballoon ablation for combined pulmonary vein isolation and left atrial roof ablation in patients with persistent atrial fibrillation?
High acute success rates were similar across modalities; hypothesis-generating for PFA versus cryoballoon in persistent AF, warranting RCTs.
BACKGROUND: Single-shot ablation systems are widely used for pulmonary vein isolation (PVI) in atrial fibrillation (AF). The use of novel pulsed-field ablation (PFA) systems enables ablation beyond PVI, such as left atrial roof ablation (LARA), which may improve outcomes in persistent AF. OBJECTIVE: This study aimed to compare the acute efficacy, feasibility, and safety of PVI combined with LARA using three different single-shot ablation systems in patients with persistent AF and left atrial enlargement undergoing their first AF ablation. METHODS: Consecutive patients undergoing PVI with LARA using cryoballoon or PFA systems were included. Baseline characteristics, procedural parameters, and complication rates were assessed. RESULTS: We included 125 patients with persistent AF and left atrial dilation, divided into cryoballoon (n = 65), pentaspline PFA (n = 30), and circular PFA (n = 30) groups. Acute PVI was achieved in 100% of veins. Fewer applications were required for LARA with cryoballoon vs. PFA (4 vs. 8 vs. 10, P < 0.001). Conduction block was confirmed in 95%, 100%, and 100% of patients (P = 0.421). Procedural times were longer with cryoballoon (87.0 vs. 64.0 vs. 68.0 min, P < 0.001), but fluoroscopy times were shorter (12.2 vs. 15.3 vs. 15.1 min, P = 0.002). Contrast medium use was higher in the cryoballoon group (P < 0.001). Adverse events were rare and predominantly minor, with three complications in the cryoballoon group and one in the PFA groups (P = 0.493). CONCLUSION: All single-shot ablation systems demonstrated comparable efficacy and safety for PVI and LARA, with differences in procedural feasibility. Further and larger studies are needed.
No takes yet. Share an insight, caveat, or question.
Yogarajah et al. (2025) conducted an observational in Persistent atrial fibrillation with left atrial enlargement (n=125). Pulsed-field ablation (pentaspline or circular) vs. Cryoballoon ablation was evaluated on Acute procedural success (complete pulmonary vein isolation and bidirectional conduction block across the left atrial roof) (p=0.421). Pulsed-field ablation and cryoballoon ablation demonstrated comparable acute efficacy, achieving 100% pulmonary vein isolation and 95-100% left atrial roof conduction block (P=0.421).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: