A simple optic-fiber Fabry-Perot (FP) sensing technique was proposed and experimentally investigated by using polymer material to connect the ends of two singlemode fibers. Four different polymer materials (benzocyclobutene (BCB), UV88 (Relentless, China), Loctite3525 (HenKel, Germany), and NOA68 (Norland, USA)) filling the FP cavity were used to comparatively study the sensing performance of temperature, strain and refractive index. The result shows that the FP sensor with BCB has excellent repeatability with good linear response to temperature in a wide range from room temperature to 250 °C, which is much larger than that of other three materials (2)) and the best repeatability among the four polymer materials.