No AccessJournal of UrologyClinical Urology: Original Article1 Aug 1996Penile Curvatures and Aneurysmal Defects with the Ultrex Penile Prosthesis Corrected with Insertion of the AMS700CX John J. Kowalczyk and John J. Mulcahy John J. KowalczykJohn J. Kowalczyk More articles by this author and John J. MulcahyJohn J. Mulcahy More articles by this author View All Author Informationhttps://doi.org/10.1016/S0022-5347(01)65859-2AboutFull TextPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract Purpose: We reviewed our series of patients with an AMS700 Ultrex* penile prosthesis whose erectile deformities were corrected by replacement with AMS700CX cylinders. American Medical Systems, Minnetonka, Minnesota. Materials and Methods: Ultrex cylinders were replaced by AMS700CX cylinders in 7 men with erectile deformities. Results: Deformities were corrected successfully in all 7 patients. The penis is completely straight in 6 patients, while a mild 30-degree ventral curvature is present in 1. Conclusions: Erectile deformities with the AMS700 Ultrex penile prosthesis can be repaired successfully by replacement with the AMS700CX cylinders. References 1 : Impotence: help for erectile dysfunction. Patient Care1994; 28: 22. Google Scholar 2 : Accuracy of the initial history and physical examination to establish the etiology of erectile dysfunction. Urology1995; 45: 498. Google Scholar 3 : Penile prostheses. In: Impotence: Diagnosis and Management of Erectile Dysfunction. Edited by . Philadelphia: W. B. Saunders Co.1994: 257. chapt. 19. Google Scholar 4 : Ten years of experience with various penile prosthesis in Korean. Yonsei Med. J.1994; 35: 209. Google Scholar 5 : The management of complications of penile implants. Probl. Urol.1991; 5: 608. Google Scholar 6 : Long-term experience with controlled expansion cylinders in the AMS 700CX inflatable penile prosthesis and comparison with earlier versions of the Scott inflatable penile prosthesis. Urology1994; 44: 400. Google Scholar 7 : Intraluminal device pressures in 3-piece inflatable penile prostheses: the "pathophysiology" of mechanical malfunction. J. Urol.1993; 149: 295. Abstract, Google Scholar 8 : Early experience with the controlled girth and length expanding cylinder of the American Medical Systems Ultrex penile prosthesis. J. Urol.1992; 148: 1444. Link, Google Scholar 9 : The inflatable penile prosthesis: clinical experience with a new controlled expansion cylinder. J. Urol.1988; 139: 945. Link, Google Scholar 10 : The "S" deformity: a complication of AMS 700 Ultrex penile prosthesis. Int. J. Impotence Res.1994; 6: D168. Google Scholar Department of Urology, Indiana University Medical Center and Indiana University School of Medicine, Indianapolis, Indiana.© 1996 by American Urological Association, Inc.FiguresReferencesRelatedDetailsCited byMILBANK A, MONTAGUE D, ANGERMEIER K, LAKIN M and WORLEY S (2018) Mechanical Failure of the American Medical Systems Ultrex Inflatable Penile Prosthesis: Before and After 1993 Structural ModificationJournal of Urology, VOL. 167, NO. 6, (2502-2506), Online publication date: 1-Jun-2002.Daitch J, Angermeier K, Lakin M, Ingleright B and Montague D (2018) LONG-TERM MECHANICAL RELIABILITY OF AMS 700 SERIES INFLATABLE PENILE PROSTHESES: COMPARISON OF CX/CXM AND ULTREX CYLINDERSJournal of Urology, VOL. 158, NO. 4, (1400-1402), Online publication date: 1-Oct-1997. Volume 156Issue 2August 1996Page: 398-401 Advertisement Copyright & Permissions© 1996 by American Urological Association, Inc.MetricsAuthor Information John J. Kowalczyk More articles by this author John J. Mulcahy More articles by this author Expand All Advertisement PDF downloadLoading ...
No takes yet. Share an insight, caveat, or question.
Kowalczyk et al. (1996) studied this question.