Why the study?
To analyze differences in systolic and diastolic left ventricular and left atrial function parameters obtained during inspiratory breath-holding versus breathing using cardiac MR imaging.
Does inspiratory breath-holding compared to free breathing alter left ventricular and left atrial function parameters assessed by cardiac magnetic resonance imaging in subjects without heart failure?
Does inspiratory breath-holding compared to free breathing alter left ventricular and left atrial function parameters assessed by cardiac magnetic resonance imaging in subjects without heart failure?
Systolic and diastolic LV and LA function parameters differ significantly when acquired during inspiratory breath-holding versus free breathing, highlighting the need for consistent respiratory states during serial CMR assessments.
PURPOSE: To analyze differences in systolic and diastolic left ventricular (LV) as well as left atrial (LA) function parameters obtained from identical cardiac magnetic resonance (MR) imaging techniques during inspiratory breath-holding and breathing (breath-hold to breathing differences). METHOD: 56 subjects without signs of heart failure (23/33 male/female, age 58 ± 14 years) underwent 3 T MR cine real-time and transmitral phase contrast imaging with the same spatial and temporal resolution during inspiratory breath-holding and free breathing. LV and LA volumetric function parameters were derived from segmentation of cine series, transmitral peak velocities and early-diastolic myocardial peak velocity from phase contrast series. Corresponding breath-hold and breathing parameters were compared by Bland-Altman analysis; repeatability of breath-hold and breathing measurements was quantified by variance component analysis. p < 0.05 was regarded as statistically significant. RESULTS: Mean differences between results obtained during inspiratory breath-holding vs. breathing were significant for LV volumetric function (end-diastolic volume=-7 mL, p = 0.002; end-systolic volume=-7 mL, p < 0.001; ejection fraction = 3 %, p < 0.001; peak ejection rate = 22 mL/s, p = 0.002; early-diastolic peak filling rate=-34 mL/s, p = 0.025), LA volumetric function (maximum volume=-6 mL, p < 0.001; total ejection fraction=-4%, p < 0.001; active ejection fraction=-2%, p = 0.013; before contraction ejection fraction=-4%, p < 0.001) and early-diastolic velocities (transmitral=-6 cm/s, p < 0.001; tissue velocity=-1.8 cm/s, p < 0.001). Standard deviations of breath-hold-to-breathing differences exceeded the corresponding repeatabilities of breath-hold and breathing measurements. CONCLUSIONS: Systolic and diastolic LV and LA function parameters acquired during inspiratory breath-holding and breathing differ, and large inter-individual breath-hold-to-breathing variations are possible. Thus, the breathing state should be taken into account, especially when comparing results in patient follow-up acquired in different respiratory states.
No takes yet. Share an insight, caveat, or question.
Reiter et al. (2021) studied this question.