BACKGROUND: Many interventions have been implemented to improve hand hygiene compliance, each with varying effects and monetary costs. Although some previous studies have addressed the issue of conspicuousness, we found only 1 study that considered improving hand hygiene by using flashing lights. METHOD: Our attention theory-based hypothesis tested whether a simple red light flashing at 2-3 Hz affixed to the alcohol gel dispensers, within the main hospital entrance, would increase hand hygiene compliance over the baseline rate. Baseline and intervention observations were completed over five 60-minute periods (Monday-Friday) from 7:30 to 8:30 AM using a covert observation method. RESULTS: Baseline hand hygiene compliance was 12.4%. Our intervention increased compliance to 23.5% during cold weather and 27.1% during warm weather. Overall, our pooled compliance rate increased to 25.3% (P < .0001). CONCLUSIONS: A simple, inexpensive flashing red light affixed to alcohol gel dispensers was sufficiently salient to approximately double overall hand hygiene compliance within the main hospital entrance. We hypothesize that our intervention drew attention to the dispensers, which then reminded employees and visitors alike to wash their hands. Compliance was worse during cold days, presumably related to more individuals wearing gloves.
No takes yet. Share an insight, caveat, or question.
D’Egidio et al. (2014) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: