Answers are grounded in this paper and cite their sources.
This paper presents a comprehensive analysis of permanent magnet synchronous machine stator winding impedance variation in inter-turn short-circuit and eccentricity faults. The phase impedances are monitored through an extended self-commissioning procedure at the standstill mode before or after operation, and hence are agnostic to well-known issues caused by transients, load/speed level, or controller coefficient dependency. Moreover, the effect of stator iron core saturation on the electrical parameters is analyzed in depth. In order to distinguish the inter-turn shorts from the eccentricity fault which exhibits similar behaviors, a classification algorithm based on the saturation effect is introduced and analyzed on the machines with different pole-slot combinations. Both two-dimensional finite element analysis simulation and experimental test results are provided to show the efficacy of this analysis.
No takes yet. Share an insight, caveat, or question.
Yuan et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: