The aim of this study was to assess the accuracy of double-contrast magnetic resonance imaging (MRI) with rectal application of the superparamagnetic iron oxide contrast agent (SPIO) ferristene and IV gadodiamide for preoperative staging of rectal cancer. In a randomized phase II dose-ranging trial, 113 patients were studied preoperatively with one of four different formulations of ferristene (Abdoscan) as an enema before MRI. T1-weighted spin-echo (T1w SE) and T2w turbo spin-echo (TSE) single-contrast images were obtained as well as T1w SE and gradient-echo (GRE) double-contrast images after IV gadodiamide injection (Omniscan). Images were assessed qualitatively, and TNM tumor stage was compared with histopathology. High-viscosity ferristene formulations were superior to low-viscosity formulations in tumor staging (accuracy 90% vs 74%, P < 0.01). There was no significant difference between high and low iron content ferristene. MRI had a sensitivity of 97%, specificity of 50%, and accuracy of 82% for staging of rectal carcinoma higher than T2 stage. At receiver operator characteristic (ROC) analysis, MR differentiation between T1/T2 and T3/T4 tumor stages yielded a ROC index of 0.848. Double-contrast MRI is an accurate method for preoperative staging of rectal cancer.
No takes yet. Share an insight, caveat, or question.
Maier et al. (2000) studied this question.