This paper proposes a circuit analysis and system modeling of an ozone generator using a phase-shifted pulsewidth modulation full-bridge inverter connected to two electrodes via a step-up transformer. The circuit operation of the inverter is fully described. Approximate models of the high-frequency transformer and the ozone-generating tube are given. Model parameter values are obtained from electrical characteristic measurement in conjunction with physical dimension calculation. In order to ensure that a zero-voltage soft-switching mode always operates over a certain range of a frequency variation, a series compensated resonant inductor is included. The advantage of the proposed system is a capability of varying ozone gas production quantity by varying the frequency of the inverter while the applied electrode voltage is kept constant, in order to overcome a high-frequency effect on the transformer voltage regulation. As a consequence, the absolute ozone production affected by the frequency is possibly achieved. The correctness and validity of the proposed system are verified by both simulation and experimental results.
No takes yet. Share an insight, caveat, or question.
Kinnares et al. (2010) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: