Why the study?
The LARIAT epicardial suture snaring device was associated with technical challenges and procedural complications, but technique modification and improved operator experience have evolved over time.
Does the LARIAT epicardial suture snaring device effectively and safely close the left atrial appendage?
Does the LARIAT epicardial suture snaring device effectively and safely close the left atrial appendage?
The LARIAT device is effective for epicardial left atrial appendage closure, with procedural safety improving over time through technique modifications such as the use of micropuncture needles and prophylactic colchicine.
Supports LARIAT for durable LAA closure; confirms high sustained efficacy via systematic synthesis.
Introduction The LARIAT epicardial suture snaring device has been fraught with technical challenges and procedural complications. Over time, technique modification and improved operator experience have helped overcome many of these challenges. Methods and Results Studies reporting left atrial appendage epicardial closure over a 12‐year period from 2009 to 2020 were evaluated. The primary efficacy outcome evaluated was left atrial appendage closure with residual flow ≤1 mm. Safety outcomes evaluated were periprocedural and long term complications after device placement. Nine studies consisting of 1430 patients were included in this analysis, of which 1386 (97%) underwent successful device placement. The mean age was 69.3 years, with a mean CHADS 2 ‐VASC score of 3.78. Primary efficacy end point was achieved in 95.8% patients immediately after device placement, and in 92.8% patients on long term follow‐up. Early procedural complications consisted of pericardial effusion 5.6%, cardiac perforation 2.7%, pericarditis 2.6%, and need for open heart surgery 1.5%. Long term complications consisted of all‐cause mortality 2.3%, stroke 1.5%, and left atrial appendage thrombus 2.3%. Reduced complications were noted using micropuncture needles (2.20% vs. 10.14%; p < .0001), a longer duration pericardial drainage, and use of anti‐inflammatory medications (1.58% vs. 8.4%). Oral anticoagulation use decreased from 44.7% to 22.9% post device implantation, and to 8.5% on last clinical follow up. Conclusions The LARIAT device is effective in epicardial closure of the left atrial appendage. Improvement in device techniques such as use of micropuncture needle, prophylactic colchicine, and maintenance of a pericardial drain have helped improve safety over time.
No takes yet. Share an insight, caveat, or question.
Sabzwari et al. (2021) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: