Why the study?
The study aimed to assess the safety and efficacy of the TightRail mechanical sheath for pacemaker and defibrillator transvenous lead extraction.
Is the TightRail mechanical sheath safe and effective for transvenous lead extraction in patients with pacemaker or defibrillator leads?
Is the TightRail mechanical sheath safe and effective for transvenous lead extraction in patients with pacemaker or defibrillator leads?
The TightRail mechanical sheath demonstrates a high clinical success rate (93%) and satisfactory safety profile (3% major complications) for transvenous lead extraction, even in older leads.
Answers are grounded in this paper and cite their sources.
Supports TightRail for TLE in low-volume centers; leaves open randomized comparisons to established tools.
INTRODUCTION: The aim of this study was to assess the safety and efficacy of the TightRail™ sheath for pacemaker/defibrillator transvenous lead extraction (TLE). METHODS: Multicenter observational study including patients who underwent a TLE with the TightRail™ sheath in five French university hospitals from September 2014 to January 2020. RESULTS: Two hundred and twenty-five patients (76% males, 71 ± 12 years) underwent a TLE procedure with the TightRail™. A total of 438 leads were extracted using the TightRail™, and the mean age of the extracted leads was 128 ± 85 months; of these, 344 (79%) were pacing leads and 94 (21%) were implantable cardioverter defibrillator leads. The overall clinical success of the extraction procedures was 93%. Overall, 410 of the 438 leads (95%) were extracted (complete or incomplete removal). After multilevel mixed-effects logistic regression model, we found that lead age (odds ratio [OR], 95% confidence interval [CI] for a 1 year increase: 1.11 [1.07-1.15], p < .001) and number of leads extracted (OR, 95% CI: 2.09 [1.50-2.96], p < .001) were the two independent factors associated with complete lead removal failure. Finally, there were 7 (3%) cases of major complications but no per-procedural death. CONCLUSION: This is the first large-scale survey assessing the efficacy and safety profile of the Tightrail™ mechanical sheath. The clinical success rate was 93%, and the lead removal failure was dependent on the age and number of leads. We show a satisfactory safety profile in this cohort of patients from primarily low-volume centers with older leads.
No takes yet. Share an insight, caveat, or question.
Artus et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: