Why the study?
Powered extraction tools are usually needed for chronically implanted leads, but comparative data between different rotating dilator sheaths were needed.
Does the Evolution rotational mechanical dilator sheath compared to the TightRail sheath improve procedural success or reduce adverse events in patients undergoing lead extraction?
Does the Evolution rotational mechanical dilator sheath compared to the TightRail sheath improve procedural success or reduce adverse events in patients undergoing lead extraction?
Both Evolution and TightRail rotational extraction sheaths demonstrate high procedural and clinical success rates with low complication rates for chronically implanted lead extraction, with no significant difference between the two devices.
Sheath selection should not yet change practice; leaves open whether Evolution or TightRail is superior for lead extraction.
INTRODUCTION: Powered extraction tools are usually needed in chronically implanted leads. Comparative data are essential among different rotating dilator sheaths. The aim of the study was to compare procedural/clinical outcomes and adverse events in patients underwent lead extraction utilizing two different rotating dilator sheaths. METHODS AND RESULTS: The current study was a retrospective review of consecutive patients at a single center. From December 2009 to August 2017, 163 lead extractions from 98 consecutive patients (median, 65 years; 71% male) utilizing a rotating mechanical sheath were analyzed for both efficacy (procedural and clinical success rates) and safety (adverse events). According to the type of the sheath used, the Evolution group (58 patients with 94 leads) and the TightRail group (40 patients with 69 leads) were determined. Extracted device was an implantable cardioverter-defibrillator (ICD) in two-thirds of patients. The majority of leads (87.7%) had passive-fixation mechanism. All ICD leads had dual-coil design. The median lead implant duration was 4 years, and no difference was found between the two groups. Infectious etiology was the main indication for extraction in 56.1% of patients. There were no statistically significant differences regarding the procedural success rate (96.6% vs 95.0%), clinical success rate (98.3% vs 97.5%), and total adverse event rate (5.2% vs 10.0%) between the Evolution and TightRail groups, respectively. Procedural success decreased with older leads and higher lead number. CONCLUSIONS: Procedural and clinical success rates utilizing both the Evolution and TightRail rotational extraction sheaths were high with low complication rate in chronically implanted leads.
No takes yet. Share an insight, caveat, or question.
Çay et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: