Answers are grounded in this paper and cite their sources.
The use of capacitance sensors is one of the methods used to quantitatively measure soil water contents (theta, m³ m-3). Sensors provide readings at desired depths and time intervals. A capacitance probe (Diviner 2000) was calibrated for a Rhodic Paleudult from the Piaui State, Brazil. Six access tubes were installed in a 5 × 2 m grid arrangement. Three moisture levels (saturated, moist and dry) were used in two replications. Probe readings and soil samplings to determine theta were made at 0.1 m depth intervals down to a depth of 1.0 m. A power calibration equation was developed for each depth as well as for the entire soil profile (Root Mean Square Error = 0.014, R² = 0.93) for a theta range of 0.068 to 0.264 m³m-3. A separate calibration for each depth improves the correlation coefficient and minimizes RMSE. Site-specific calibration improves the accuracy for soil water monitoring.
No takes yet. Share an insight, caveat, or question.
Silva et al. (2007) studied this question.