Achieving steady-state plasma operation at high plasma temperatures is one of the important goals of worldwide magnetic fusion research. A high temperature of approximately 2keV, and steady-state plasma-sustainment operation of the Large Helical Device (LHD) [O. Motojima, K. Akaishi, H. Chikaraishi et al., Nucl. Fusion 40, 599 (2000)] is reported. High-temperature plasmas were created and maintained for more than 30min with a world record injected heating power of 1.3GJ. The three-dimensional heat-deposition profile of the LHD helical divertor was modified and during long-pulse discharges it effectively dispersed the heat load using a magnetic-axis swing technique developed at the LHD. A sweep of only 3cm of the major radius of the magnetic axis position (less than 1% of the major radius of the LHD) was enough to disperse the divertor heat load. The modification of the heat-load profile was explained well by field-line tracing. The steady-state plasma was heated and sustained mainly by hydrogen minority ion heating using ion cyclotron range of frequencies. The operation lasted until a sudden increase of radiation loss occurred, presumably because of wall metal flakes dropping into the plasma. The sustained line-averaged electron density was approximately 0.7–0.8×1019m−3. The average input power was 680kW, and the plasma duration was 31min 45s. This successful long operation shows that the heliotron configuration has a high potential as a steady-state fusion reactor.