Answers are grounded in this paper and cite their sources.
• Comparative evaluation of 3D-printed TPU/CB strain sensors fabricated from two commercial conductive filaments (RECREUS and FILI). • RECREUS sensors show higher ductility and negative piezoresistive response; FILI sensors exhibit positive, highly linear behavior at low strain. • TPU/CB/Ag FILI sensors demonstrate minimal baseline drift (<6%) after 500 cycles, confirming superior long-term durability. Commercially available conductive filaments offer a suitable option for rapidly fabricating piezoresistive strain sensors using additive manufacturing technologies. Extending previous work on the RECREUS-based sensors, this study presents a comparative evaluation of the electromechanical performance of strain sensors fabricated from two thermoplastic polyurethane (TPU) filaments loaded with carbon black (CB): RECREUS and FILI. These filaments were processed via fused filament fabrication (FFF) to form TPU/CB sensors. To enhance electrical performance, silver interdigitated electrodes were integrated onto the sensor surfaces using direct ink writing (DIW), resulting in hybrid TPU/CB/Ag configurations. The sensors were characterized under quasi-static and dynamic tensile loading to assess their sensitivity, hysteresis, and durability. Sensors fabricated with RECREUS filament exhibited a negative piezoresistive response and high stretchability, with gauge factors ranging from approximately −18.61 to −0.29 for TPU/CB and from −23.78 to 0.45 for TPU/CB/Ag across the entire strain range. In contrast, FILI-based sensors showed a positive, highly linear response at low strain, with gauge factors of approximately 12–123 for TPU/CB and ≈16 for TPU/CB/Ag. The integration of silver electrodes improved electrical stability and reduced hysteresis in both sensor types. During cyclic loading with small strains between 0.2% and 5%, both materials generated an electrical response proportional to the deformation; however, only the FILI-based sensors kept a stable baseline with minimal drift. After 500 cycles, the FILI sensors showed less than 6% signal drift, compared with 27% drift observed in the RECREUS sensors. These findings highlight the influence of filler dispersion and electrode-to-polymer compatibility on sensor reliability and demonstrate that commercially available filaments with nominally similar compositions can exhibit significantly different electromechanical behavior, affecting sensor reliability.
No takes yet. Share an insight, caveat, or question.
Sánchez et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: