This paper presents a passive wireless sensor for simultaneously and remotely measuring pressure and temperature under harsh environments. The sensor consists of a dual LC (inductor and capacitor) resonant circuit, one without a cavity and the other with a cavity capacitor for temperature and pressure sensing, respectively. The low-temperature co-fired ceramic technology is used to fabricate the sensor, making it suitable for high-temperature harsh environment operations. Experimental results show the prototype sensor has temperature sensitivity of 8.15 kHz/°C and pressure sensitivity of 1.96 MHz/Bar up to 400°C.
No takes yet. Share an insight, caveat, or question.
Tan et al. (2017) studied this question.