Answers are grounded in this paper and cite their sources.
This paper proposes a control method to null the magnet flux in an interior permanent-magnet (IPM) motor following short-circuit-type faults in either the inverter drive or motor stator windings. Phase-based control is employed to implement the flux-nulling-control method so that it is possible to take advantage of a zero-sequence current in order to minimize the current in the shorted phase. It is shown that phase-based control results in a smaller induced current than when employing a synchronous-frame dq0 current regulator. The induced torque is also less than that when employing a purposely commanded symmetrical short circuit in response to a short-circuit-type fault. In the paper, the complete magnet-flux-nulling-control algorithm is derived with reference to the proposed phase-current-control method. The impact of controlling the zero-sequence current on the resulting phase currents is presented. Both simulation and experimental results are presented, verifying the operation of the proposed methods.
No takes yet. Share an insight, caveat, or question.
Welchko et al. (2006) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: