The present study is the second half of a piece of work carried out in collaboration with SNECMA. It investigates shaped hole film cooling, numerically and experimentally. The aim of this paper is the experimental analysis of shaped hole film cooling on a large scale turbine blade (1.4 m chord). The test section is a large scale turbine inlet guide vane cascade. The test airfoil is equipped with a row of nine 50 degrees sloped shaped holes. They are located on the suction side at 20% of the curvilinear length of the blade from the stagnation point. The inlet film cooling hole diameter is 12 mm. The jet flow is heated to 55 degrees C above the crossflow temperature. Velocity and temperature field measurements have been done to obtain mean and fluctuating values. The results are compared to those obtained by Béral on the same experimental apparatus and in the same test conditions, for a row of cylindrical holes.
No takes yet. Share an insight, caveat, or question.
Barthet et al. (2001) studied this question.