Key result
CTP-angiographic reconstructions match conventional CTA for occlusion detection in acute ischemic stroke.
Why the study?
Does CTP-AR provide comparable diagnostic accuracy to conventional CTA for occlusion detection in ischemic stroke patients?
Observational (n=210)
Does CTP-AR provide comparable diagnostic accuracy to conventional CTA for occlusion detection in ischemic stroke patients?
Absolute Event Rate: 89% vs 90%
CTP-AR has comparable diagnostic accuracy to conventional CTA for detecting occlusions in ischemic stroke, suggesting it could be used to conserve contrast medium.
BACKGROUND: Both CT angiography and CT perfusion involve the administration and tracking of a contrast medium bolus for different purposes. In this study, we aim to compare the diagnostic accuracy and subjective image quality of CTP-angiographic reconstructions with conventional CTA for occlusion detection in ischemic stroke patients. METHODS: In this retrospective study, patients with a final diagnosis of ischemic stroke and who underwent both CTA and CTP from September 2020 up to and including September 2021 were included. CTP-AR was reconstructed from the 1 mm CTP series at the time of maximum arterial inflow. Three reviewers with different levels of experience assessed both CTA and CTP for occlusion detection, expressed certainty, and rated subjective image quality. The reference standard was set at the consensus meeting. Pooled sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Differences in subjective and objective image quality and certainty were assessed using Kendall's tau correlation and paired samples t-tests. RESULTS: In total, 107/210 included patients had an occlusion based on our reference standard. Pooled sensitivity and specificity for occlusion detection were 90% (95%CI 85-93) and 94% (95%CI 90-97) for CTA, and 89% (95%CI 84-93) and 93% (95%CI 89-96) for CTP-AR, respectively. The pooled certainty did not significantly differ between CTA and CTP-AR (P=.43). The pooled subjective image quality scores significantly differed between CTA and CTP-AR (τ = 0.3, P<.001), where one reviewer rated subjective image quality higher in CTA and two reviewer in CTP-AR. CONCLUSION: CTP-AR has comparable diagnostic accuracy to conventional CTA imaging for occlusion detection in ischemic stroke patients. Thus, using CTP-AR instead of CTA plus CTP may conserve contrast medium.
No takes yet. Share an insight, caveat, or question.
Robbe et al. (2024) conducted an observational in ischemic stroke (n=210). CTP-angiographic reconstructions (CTP-AR) vs. conventional CTA was evaluated on pooled sensitivity for occlusion detection. CTP-angiographic reconstructions demonstrated comparable diagnostic accuracy to conventional CTA for occlusion detection in ischemic stroke patients, with a pooled sensitivity of 89% versus 90%.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: