Why the study?
Dialysis causes myocardial blood flow defects that may augment electrophysiological heterogeneity via increased ischemic zones, but whether more ischemic zones aggravate arrhythmia remained to be tested computationally.
Does a larger number of ischemic zones aggravate arrhythmia in a computational model of the human ventricle?
Does a larger number of ischemic zones aggravate arrhythmia in a computational model of the human ventricle?
Computational modeling suggests that increased ischemic heterogeneity, such as that caused by dialysis, can provide a substrate for severe arrhythmias and fibrillation.
Increased ischemic heterogeneity may promote fibrillation in ventricular models; leaves open clinical relevance in patients.
Dialysis causes blood flow defects in the heart that may augment electrophysiological heterogeneity in the form of increased number of ischemic zones in the human left ventricle. We computationally tested whether a larger number of ischemic zones aggravate arrhythmia using a 2D electrophysiological model of the human ventricle.A human ventricle cardiomyocyte model capable of simulating ischemic action potentials was adapted in this study. The cell model was incorporated into a spatial 2D model consisting of known number of ischemic zones. Inter-cellular gap junction coupling within ischemic zones was reduced to simulate slow conduction. Arrhythmia severity was assessed by inducing a re-entry, and quantifying the ensuing breakup and tissue pacing rates.Ischemia elevated the isolated cardiomyocyte’s resting potential and reduced its action potential duration. In the absence of ischemic zones, the propensity in the 2D model to induce multiple re-entrant waves was low. The inclusion of ischemic zones provided the substrate for initiation of re-entrant waves leading to fibrillation. Dominant frequency, which measured the highest rate of pacing in the tissue, increased drastically with the inclusion of multiple ischemic zones. Re-entrant wave tip maximum numbers increased from 1 tip (no ischemic zone) to 34 tips when a large number (20) of ischemic zones were included. Computational limiting factors of our platform were identified using software profiling.Clinical significance. Dialysis may promote deleterious arrhythmias by increasing tissue level action potential dispersion.
No takes yet. Share an insight, caveat, or question.
Sanjay Kharche (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: