The retro analog of the HER2-targeting A9 peptide was synthesized by coupling amino acids in a reverse fashion and switching the N-terminal in the original sequence of the L-A9 peptide (QDVNTAVAW) to the C-terminal in rL-A9 (WAVATNVDQ). Modification in the backbone resulted in higher conformational stability of the retro peptide as evident from CD spectra. Molecular docking analysis revealed a higher HER2 binding affinity of [ 177 Lu]Lu-DOTA-rL-A9 than the original radiopeptide [ 177 Lu]Lu-DOTA-L-A9. Enormously enhanced metabolic stability of the retro analog led to significant elevation in tumor uptake and retention. SPECT imaging studies corroborated biodistribution results demonstrating a remarkably higher tumor signal for [ 177 Lu]Lu-DOTA-rL-A9. The presently studied retro probe has promising efficiency for clinical screening.
No takes yet. Share an insight, caveat, or question.
Sharma et al. (2023) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: