Answers are grounded in this paper and cite their sources.
An accurate nonlinear model is necessary to optimize the tradeoff between efficiency and linearity in power amplifiers. Gain compression (AM/AM) and amplitude-phase (AM/PM) distortion are the two primary model inputs used to characterize the nonlinearity. The amplifier's AM/AM and AM/PM characteristics are typically measured statically using a vector network analyzer. Since the input is typically a modulated signal, it is desirable to characterize the amplifier dynamically. This paper describes and demonstrates a dynamic AM/AM and AM/PM measurement and modeling technique involving a spectrum analyzer and two-tone input signals. A complete analysis of the measurement technique is presented, along with the data processing needed for the identification of a new three-box model. The test configuration and procedure are presented with special precautions to minimize measurement error. Results for a solid-state amplifier are used to accurately predict intermodulation distortion, while those for a traveling-wave tube amplifier show good agreement with that obtained dynamically using a 16 quadrature-amplitude-modulation signal.
No takes yet. Share an insight, caveat, or question.
Clark et al. (2002) studied this question.